Command Line Reference
Ethernet Interface Commands
shutdown
This command disables the Ethernet interface. To restart a disabled interface,
use the no form.
Syntax
shutdown
no shutdown
Default Setting
Interface enabled
Command Mode
Interface Configuration (Ethernet)
Command Usage
This command allows you to disable the Ethernet interface due to
abnormal behavior (e.g., excessive collisions), and re-enable it after the
problem has been resolved. You may also want to disable the Ethernet
interface for security reasons.
Example
The following example disables the Ethernet interface.
HP420(if-ethernet)#shutdown
HP420(if-ethernet)#
speed-duplex
This command configures the speed and duplex mode of the Ethernet inter-
face when auto-negotiation is disabled. Use the no form to restore the default.
Syntax
speed-duplex <auto | 10MH | 10MF | 100MH | 100MF>
auto - autonegotiate the speed and duplex mode
10MH - Forces 10 Mbps, half-duplex operation
10MF - Forces 10 Mbps, full-duplex operation
100MH - Forces 100 Mbps, half-duplex operation
100MF - Forces 100 Mbps, full-duplex operation